CONSTRUCTION
Analysis Protocol for motor’s electrical and mechanical conditions
Electrical testing protocol with Baker Dx SKF
Parts marking
Motor disassembling (caps and rotor removal)
Bearings disassembling
Review and analysis of stator’s internal connection and magnetic wire calibration
Damaged winding removal
Laminate cleaning
Removal of previous paint layer by sand blasting - Capping of bearing housings
Metallized handles in the bearing area – Bearings replacement
Seal change (when necessary)
Fan replacement (when necessary) - Class F and H insulation preparation
Manufacturing of preformed electric coil sets based on Condumex Magneto Universanel 200 ° C wire
Manufacturing of preformed stator coil set based on Magneto Corona Guard wire, for motors working with a frequency inverter
Stator winding
Bearing mounting with SKF induction heater
Dynamic balancing of the rotor and rotating components (turbines)
Engine assembly
General cleaning and painting