S E R V I C E S

CONSTRUCTION

Responsive devices

  Analysis Protocol for motor’s electrical and mechanical conditions
  Electrical testing protocol with Baker Dx SKF
  Parts marking
  Motor disassembling (caps and rotor removal)
  Bearings disassembling
  Review and analysis of stator’s internal connection and magnetic wire calibration
  Damaged winding removal
  Laminate cleaning
  Removal of previous paint layer by sand blasting - Capping of bearing housings
  Metallized handles in the bearing area – Bearings replacement
  Seal change (when necessary)
  Fan replacement (when necessary) - Class F and H insulation preparation
  Manufacturing of preformed electric coil sets based on Condumex Magneto Universanel 200 ° C wire
  Manufacturing of preformed stator coil set based on Magneto Corona Guard wire, for motors working with a frequency inverter
  Stator winding
  Bearing mounting with SKF induction heater
  Dynamic balancing of the rotor and rotating components (turbines)
  Engine assembly
  General cleaning and painting